ANSI Code | Alloy Combination | Colour Coding | Maximum Temperature Useful Range | EMF (mV) Over Max. Temperature Range | Limits of Error** (Whichever is Greater) | |||||
---|---|---|---|---|---|---|---|---|---|---|
+Lead | -Lead | Thermocouple Grade | Extension Grade | |||||||
Standard | Special | |||||||||
E | CHROMEGA NICKEL- CHROMIUM Ni-Cr |
CONSTANTAN COPPER- NICKEL Cu-Ni |
-200 to 900°C (-328 to 1652°F) Therm. Grade 0 to 200°C (32 to 392°F) Ext. Grade |
-9.835 to 76.373 | -200 to 900°C (-328 to 1652°F)
|
|||||
N | OMEGA-P NICROSIL Ni-Cr-Si |
OMEGA-N NISIL Ni-Si-Mg |
-270 to 1300°C (-450 to 2372°F) Therm. Grade 0 to 200°C (32 to 392°F) Ext. Grade |
-4.345 to 47.513 | 2.2°C or 0.75% Above 0°C 2.2°C or 2.0% Below 0°C |
1.1°C or 0.4% | ||||
R | PLATINUM 13% RHODIUM Pt-13% Rh |
PLATINUM PT |
NONE ESTABLISHED | 0 to 1450°C (32 to 2642°F) Therm. Grade 0 to 150°C (32 to 300°F) Ext. Grade |
-0.226 to 21.101 | 0 to 1450°C (32 to 2642°F)
|
||||
S | PLATINUM 10% RHODIUM Pt-10% Rh |
PLATINUM PT |
NONE ESTABLISHED | 0 to 1450°C (32 to 2642°F) Therm. Grade 0 to 150°C (32 to 300°F) Ext. Grade |
-0.236 to 18.693 | 0 to 1450°C (32 to 2642°F)
|
ANSI CODE | International IEC 584-3 | International IEC 584-3 Intrinsically Safe | CZECH BRITISH to BS 1843 | NETHERLANDS GERMAN to DIN 43710 | JAPANESE to JIS C 1610-1981 | FRENCH to NFC 42-324 | Comments Environment - Bare Wire |
---|---|---|---|---|---|---|---|
E | Oxidising or Inert. Limited Use in Vacuum or Reducing. Highest EMF Change per Degree | ||||||
N | No Standard Use American Colour Codes |
Alternative To Type K More Stable at High Temps |
|||||
R | Oxidising or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature | ||||||
S | Oxidising or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature |